Principio e Processo di Laser Portata Finder Misurazione

Mar 15, 2023

Lasciate un messaggio

Principio e Processo di Laser Portata Finder Misurazione

 

Misurazione Principio e Metodo di Laser Portata Finder


1. What is the principle of using infraross ranging or laser ranging?


Il principio di ranging può fondamentalmente essere attribuito a misurare il tempo richiesto per luce a andare indietro e avanti a il bersaglio, e allora calcolare il distanza D attraverso il velocità di luce c=299792458}m/s e il atmosferico rifrazione indice n. Perché it è difficile a misura tempo direttamente, it è usualmente a misura la fase di continuo onda, che è chiamato fase misurazione intervallo mirino. di corso, Lì Are Anche Pulsato Telemetri.


It should be noted that phase measurement does not measure the phase of infrared or laser, but the phase of the signal modulated on infrared or laser. the construction industry has a handheld laser distance meter for house surveying that works on the same principle.


2. Deve il piano di il misurato oggetto essere perpendicolare a il luce?


Solitamente precisione distanza misura richiede il cooperazione di a totale riflessione prisma, while the telemetro usato per casa misura direttamente misure con liscio muro riflesso, principalmente perché il distanza è relativamente breve e il segnale forza di il luce riflessa indietro è grande abbastanza. It può essere conosciuto da questo quello esso deve essere verticale, altrimenti il ritorno segnale è troppo debole e il distanza nonpuò essere ottenuto.


3. Is it possible if the plane of the measured object is diffuse reflection?



4. Ultrasonic ranging accuracy is relatively low.



1mm plus 1ppm is the abbreviation of 1mm plus 1ppm×D (kilometer), which reflects the nominal ranging accuracy of the total station or rangefinder. in:
1mm represents the fixed error of the instrument, which is mainly caused by the measurement error, centering error, and phase measurement error of the instrument plus constant. The fixed error has nothing to do with the measured distance. That is, no matter how far the measured actual distance is, the total station will have a fixed error not greater than this value.
1ppm×Dkm represents the proportional error, where 1 is the proportional error coefficient, which is mainly caused by the instrument frequency error and the atmospheric refractive index error. ppm means parts per million (a few), and D is the distance value actually measured by the total station or rangefinder, in kilometers. As the actual measurement distance changes, the proportional error part of the instrument also changes proportionally. For example, when the distance is 1 km, the scale error is 1mm.
For a total station or telemetro with a ranging accuracy of 1mm plus 1ppm, when the measured distance is 1km, the ranging accuracy of the instrument is 1mm plus 1ppm×1(km)=2}mm, that is to say, the total The distance of the station instrument is 1 km, and the maximum ranging error is not more than 2mm.
3 secondi è il tempo per intervallo

 

lasr rangefinder

Invia la tua richiesta