Commutazione alimentazione elettromagnetico compatibilità termini tecnici

Dec 03, 2023

Lasciate un messaggio

Commutazione alimentazione elettromagnetico compatibilità termini tecnici

 

(1) elettromagnetico compatibilità
Compatibilità elettromagnetica si riferisce alla capacità di un dispositivo o sistema di funzionare normalmente nel suo ambiente elettromagnetico senza causare disturbi elettromagnetici intollerabili a qualsiasi cosa nel contesto.


(2) elettromagnetico molestie
Electromagnetic disturbance refers to any electromagnetic phenomenon that may cause the performance of equipment, equipment or systems to degrade or cause damage to living or inanimate substances. Electromagnetic disturbance can cause degradation of equipment, transmission channels or system performance. Its main elements include natural and man-made disturbance sources, coupling through public ground impedance/internal resistance, electromagnetic disturbance and radiated interference conducted along power lines, etc. The paths for interference in electronic systems are: through the power supply, through signal lines or control cables, field penetration, and directly through the antenna; through cable coupling, conduction interference from other equipment; internal field coupling in the electronic system; radiation interference from other equipment; Electronic equipment externally coupled to internal fields; broadband transmitter antenna systems; external environmental fields, etc.


(3) elettromagnetico ambiente
L'ambiente elettromagnetico è un fenomeno elettromagnetico variabile nel tempo che apparentemente non trasmette informazioni e può essere sovrapposto o combinato con utili segnali.


(4) elettromagnetico radiazione
Radiazione elettromagnetica si riferisce al fenomeno del fenomeno delle onde elettromagnetiche e da una sorgente nel spazio. Il significato del termine "radiazione elettromagnetica" può talvolta essere esteso per includere il fenomeno della induzione elettromagnetica. RFI/EMI può essere irradiato attraverso aperture, bocche, prese e uscite, cavi, misurazione fori, porte porte, cassetti e pannelli di qualsiasi apparecchiatura valigetta, come bene come non-ideale connessione superfici della custodia. RFI/EMI può anche essere irradiata da fili e cavi entrandoe apparecchiature sensibili, e qualsiasi buono radiatore di energia elettromagnetica può anche servire come un buono ricevitore.


(5) Impulso
A impulso si riferisce a una quantità fisica che muta in un breve periodo di tempo e poi rapidamente ritorna al suo valore iniziale.


(6) Comune modo interferenza e differenziale modo interferenza
There are two types of interference on power lines: common mode interference and differential mode interference. Common mode interference exists between any one of the power supply and the ground or between the wire and the ground. Common mode interference is sometimes also called longitudinal mode interference, asymmetric interference or ground interference. This is the interference between the current-carrying conductor and the earth. Differential mode interference exists between the power supply phase line and the neutral line and between the phase line and the phase line. Differential mode interference is also called normal mode interference, transverse mode interference or symmetrical interference. This is interference between current-carrying conductors. Common mode interference indicates that the interference is coupled into the circuit by radiation or crosstalk, while differential mode interference indicates that the interference originates from the same power circuit. Usually these two interferences exist at the same time. Due to the imbalance of line impedance, the two interferences will transform into each other during transmission, so the situation is very complicated. After the interference is transmitted over a long distance, the attenuation of the differential mode component is greater than that of the common mode. This is because the line-to-line impedance is different from the line-to-ground impedance. For the same reason, common mode interference will also radiate to adjacent space during line transmission, but differential mode will not, so common mode interference is more likely to cause electromagnetic interference than differential mode. Different interference methods require different interference suppression methods to be effective. An easy way to determine the interference method is to use a current probe. The current probe first surrounds each wire individually to obtain the induction value of the single wire, and then surrounds two wires (one of which is the ground wire) to detect its induction. If the induction value increases, the interference current in the line is common mode; otherwise, it is differential mode.


(7) Immunità livello e sensibilità livello
Il livello di immunità si riferisce al livello massimo di disturbo quando un dato disturbo elettromagnetico è applicato a un apparecchiatura o sistema per, e può ancora funzionare normalmente e mantenere il livello di prestazioni richiesto. Quello è, il dispositivo, apparecchiatura, o sistema sperimenterà prestazioni degradazione sopra questo livello. il livello di sensibilità è il livello a cui le prestazioni degrado inizia solo a verificarsi. Pertanto, per un qualsiasi dispositivo, apparecchiatura o sistema, il livello di immunità e il livello di sensibilità sono il stesso valore.


(8) Immunità margine
Il margine della immunità si riferisce alla interpolazione tra il livello di immunità limite e il livello di compatibilità elettromagnetica delle apparecchiature, o sistema.

 

Bench Power Source